Abstract As of the 1st January 2017 the Host/Controllers/Switches section will not longer be updated. Please use SSIC instead: The documents titled Supported Hardware List and Recommended Software Levels provide the operating systems, Host adapters, SAN fabric elements, RAID controllers and selected other hardware that have been tested or qualified by IBM. This page combines the previously separate Software and Hardware support matrices. For operating systems, we show the latest tested release levels and service packs.
Only the listed operating systems are supported. For host adapters, SAN fabric elements and RAID controllers, we list our currently recommended firmware and/or BIOS levels and formally support only the hardware listed. While these levels are not mandatory levels for a customer to be supported by IBM, they are the recommended levels.
Tango Pcb Software more. There may be known operational issues with older firmware and BIOS levels and, in these cases, a customer working with the IBM Support center may be directed to upgrade a component to a recommended level. SVC will support all OS applications at any level that run to the standard block level OS interface.
R2 sp2 download x64 iso. Windows Server 2003 R2 Standard X86. Dell OEM Windows Server 2008 Foundation x64. Windows Server 2008 r2 Standard.
This includes such applications as Oracle, HP Virtual Connect, etc. Note: * The levels shown in italic text indicate previously recommended levels. * The level shown in bold text indicates the latest recommended level. * EOL - (End of Life): Where interoperability items have gone end of life (out of support) and are no longer supported by the vendor either generally or by extended service contact IBM will continue to support the environment on a best can do basis. Where issues occur which are deemed by IBM support to be directly related to items which are no longer generally supported by the vendor IBM may direct customers to upgrade a component to a recommended level.
Whilst IBM recommends these levels based upon the most recent testing, the following levels were tested against previous versions of SVC and IBM will support the use of these levels with SVC V7.4.x If you have Interoperability requirements which are not listed in this document please contact your IBM Account Representative ------ 16Gbps Fibre Channel Node Connection Please see SSIC for supported 16Gbps Fibre Channel configurations supported with 16Gbps node hardware. Note 16Gbps Node hardware is supported when connected to Brocade and Cisco 8Gbps or 16Gbps fabrics only. Direct connections to 2Gbps or 4Gbps SAN or direct host attachment to 2Gbps or 4Gbps ports is not supported. Other configured switches which are not directly connected to the16Gbps Node hardware can be any supported fabric switch as currently listed in SSIC. *IBM highly recommends the use of SDDDSM 2.4.7.1 for clustered environments. With versions of SDDDSM earlier than 2.4.4.0 & clustered environments please see the.
Please see the following link for advice on Qlogic Fibre Channel cards are not supported attached to Cisco or Brocade FCF switches. Veritas Storage Foundations Settings The default setting of VERITAS Storage Foundation 5.1 is SCSI-2. However in Configurations with SVC or V7000 IBM recommends the use of SCSI-3 for native solution VCS + VERITAS Storage Foundation 5.1 (VSFW 5.1 HA) + DMPDSM or when using VERITAS Storage Foundation 5.1 with SDDDSM. *IBM highly recommends the use of SDDDSM 2.4.7.1 for clustered environments.
With versions of SDDDSM earlier than 2.4.4.0 & clustered environments please see the. ** HBA NodeTimeOut on Emulex adapters with Windows OS should be set to 3 seconds. Please see the.
** Veritas Storage Foundations Settings The default setting of VERITAS Storage Foundation 5.1 is SCSI-2. However in Configurations with SVC or V7000 IBM recommends the use of SCSI-3 for native solution VCS + VERITAS Storage Foundation 5.1 (VSFW 5.1 HA) + DMPDSM or when using VERITAS Storage Foundation 5.1 with SDDDSM. HP 9000 Series Servers (PA-RISC 64bit) & HP Itanium ServersThe following patches should be applied to the base OS: BUNDLE11i(B.3) HWEnable11i(B.064) FEATURE11i(B.063) QPK1123(B.064) Set PV (Physical Volume) timeout to 60 seconds when using PV Links. This is to avoid I/O timeouts during fabric maintenance and SAN Volume Controller CCLs (Concurrent code loads) BUNDLE11i B.3 Required Patch Bundle for HP-UX 11i v2 (B.11.23), FEATURE11i B.070a Feature Enablement Patches for HP-UX 11i v2, HWEnable11i B.070 Hardware Enablement Patches for HP-UX 11i v2, OnlineDiag B.11.23.10.05 HPUX 11.23 Support Tools Bundle, QPKAPPS B.072 Applications Patches for HP-UX 11i v2, QPKBASE B.072 Base Quality Pack Bundle for HP-UX 11i v2, HPUX11i-OE-MC B. HP-UX Mission Critical Operating Environment Component SDD does not support path failover when applied to raw disk. The use of PV Links is recommended. Supported OS Versions Solaris 11.0 Solaris 11.1 Solaris 11.2 Solaris 11.3 Oracle VM Server for SPARC version 3.0 For guidance on SUN Cluster in a SAN Volume Controller stretch cluster environment please refer to the An issue has been identified with certain Solaris versions that may cause I/O failures during a failover scenario.
The effected Versions are S11.1SRU20 and later, S11.2 and later, S11.2SRU The following IDRs resolve the issue and are available directly from Oracle DR1352.1 for Solaris 11.1.21.4.1 IDR1565.1 for Solaris 11.2.4.6.0 IDR1563.1 for Solaris 11.2.2.5.0, 11.2.2.7.0,11.2.2.8.0. SAN Volume Controller supports Server Blades that meet all of the following criteria; 1. The Server blade contains Qlogic and Emulex generic chip sets running the IBM or equivalent supported Drivers; and 2. These generic chip sets and drivers are present in the SAN Volume Controller support matrix for HBAs used in non Blade servers; and 3. The Server blade is running an OS that is present in the SAN Volume Controller support matrix; and 4. Either a Fibre Channel pass through module is used in the Blade server chassis to connect the Blades to an external FC network; or The Fibre Channel switch module used in the Blade server chassis is equivalent (in the sense it runs the same microcode on the same switch hardware base) to a discrete Fibre Channel switch that is already listed in the SAN Volume Controller support matrix. Examples of specific BladeCentre configurations that IBM includes in SAN Volume Controller interoperability testing currently include: IBM Flex V7000 and General Flex Systems Support.
*IBM highly recommends the use of SDDDSM 2.4.7.1 for clustered environments. With versions of SDDDSM earlier than 2.4.4.0 & clustered environments please see the.
With 90Y3566 & 90Y3550+ the BNT 10 Port 10Gb Ethernet Switch Module (PN 46C7191) and QLogic Virtual Fabric Extension Module (PN 46M6172) are required components. PN 90Y3550 must be upgraded with PN 49Y4265 (Advanced Upgrade). PNIC mode only when used with the IBM Brocade Converged 10GbE Switch Module (P/N 69Y1909) pNIC or vNIC1 mode when used with the IBM BNT 10 Port 10Gb Ethernet Switch Module (P/N 46C7191). SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot process Remove the ql2xfailover=0 parameter from the IBM modprobe.conf Supported with Emulex 11000 and QLogic 2460 With 90Y3566 & 90Y3550+ the BNT 10 Port 10Gb Ethernet Switch Module (PN 46C7191) and QLogic Virtual Fabric Extension Module (PN 46M6172) are required components.
PN 90Y3550 must be upgraded with PN 49Y4265 (Advanced Upgrade). PNIC mode only when used with the IBM Brocade Converged 10GbE Switch Module (P/N 69Y1909) pNIC or vNIC1 mode when used with the IBM BNT 10 Port 10Gb Ethernet Switch Module (P/N 46C7191). Single path SAN boot Problem: SLES 11Server x86_64 doesn't boot after OS installation on SAN disk. Problem appears when Adaptec Raid controller BIOS (local disk) and Emulex HBA BIOS are active. Solution: Host boots from SAN disk when local disk controller BIOS is disabled. Expand / shrink vdisk Warning: data loss possible!!!!! With 90Y3566 & 90Y3550+ the BNT 10 Port 10Gb Ethernet Switch Module (PN 46C7191) and QLogic Virtual Fabric Extension Module (PN 46M6172) are required components.
PN 90Y3550 must be upgraded with PN 49Y4265 (Advanced Upgrade). PNIC mode only when used with the IBM Brocade Converged 10GbE Switch Module (P/N 69Y1909) pNIC or vNIC1 mode when used with the IBM BNT 10 Port 10Gb Ethernet Switch Module (P/N 46C7191). VMware Native Multipathing Plugin (NMP) Controllers Please refer to the Configuration Guide or SAN Volume Controller Information Center which details the recommended customer configurable settings that should be applied for each storage controller type. Multipathing • Round Robin: IO is distributed over multiple ports on the controller. • Mdisk Group Balanced: IO is sent to one target port on the controller for each mdisk. The assignment of ports to mdisks is chosen to spread all the mdisks within a mdisk group across all of the active target ports as evenly as possible.
• Single port active: All IO is sent to a single port on the controller for all mdisks. • Controller Balanced: IO is sent to one target port on the controller for each mdisk.
The assignment of ports to mdisks is chosen to spread all the mdisks across all of the active target ports as evenly as possible. IBM Storwize V3700. Dynamic expansion of controller LUNs is not supported Please refer the for the latest recommended DS4000 client software and RDAC levels Please refer the for specific configuration guidelines, cabling requirements & restrictions when attaching EXP810 to DS4300 & DS4500 DS4000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SAN Volume Controller RAID-5 Array size must be 4+1 or larger.
RAID-6 Array size must be 4+1+1 or larger. DS4000 range maximum LUNs per partition is currently 256, limiting the number of LUNs from a single DS4000 to a single SAN Volume Controller cluster to 256. * Please see the following DS4K flashe s If you have 07.36.08.xx code, you MUST contact DS4000 support prior to upgrading to your DS4000 firmware. The 07.36.08.xx release is no longer supported. Dynamic expansion of controller LUNs is not supported Please refer the for the latest recommended DS5000 client software and RDAC levels Please refer the for specific configuration guidelines, cabling requirements & restrictions when attaching EXP5000 and EXP810 DS5000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SAN Volume Controller.
DS5000 range maximum LUNs per partition is currently 256, limiting the number of LUNs from a single DS5000 to a SAN Volume Controller cluster to 256. RAID-5 Array size must be 4+1 or larger RAID-6 Array size must be 4+1+1 or larger.
According to the bootup, there's a perc h700 raid controller. What I've tried: 1. Inserted the SMTD 6.5.0 DVD that came with the server.
It boots up fine.gets to the point where it ask me to insert the appropriate OS media. I'm getting “The file ‘autorun.dll’ could not be loaded or is corrupt.
Setup cannot continue. Error code is [0xC1]” The OS media is an open license one that I downloaded from MS.
There is NO autorun.dll file on the media. Boot the server straight from the w2k8 r1 with sp1 CD. Boots up fine.gets to the point where it ask me for drivers (presumably the perc h700 raid controller driver). I extracted DELL_MULTI-DEVICE_A00_R244735.exe to a USB drive. When I point the server to the drivers on the USB drive, I'm getting 'No new devices could be found.
Make sure the driver files are correct and located on the driver installation media.' But the driver I downloaded is specifically for the H700 and it's for Windows 2008 R2!!!!!!!!!!!!!!!!!! Wth is going on? This is so frustrating. My silliness.
I didn't realize that the ISO I downloaded WAS NOT COMPLETED! It was 1.6 gig in size and I neglected to check the size before I burned it.
As I've mentioned, the (bad) DVD did boot up properly in my vmware and direct on my dell server???which looking back I thought was strange. Anyways, I downloaded the ISO.making sure it's 2.9 gig total size. It's fine now.
On a side note, where during the installation process does it ask me how to partition my virtual disk? There are four 2TB disks in the server. I went into the PERC BIOS and made the four a raid 5 set. As I was installing w2k8 r2, I don't ever remember the installation process asking me how I want to partition the 6TB virtudal disk??? When it came time to copy the W2K8 R2 files over, the installation process showed me a partition that's 2TB and a partition that's close to 4TB. The DELETE command button was dimmed out so I couldn't select it.
I just picked the 2TB to install the OS. Anyone know why?
Did I miss a step? I just wanted a 1TB partition to be the OS.and the rest to be data.
Dell OEM Windows Server 2008 Foundation ISO Download Latest Version for Windows. It is full Bootable ISO Clean DVD Image of Dell OEM Windows Server 2008. Dell OEM Windows Server 2008 Foundation x64 ISO Overview Windows Server 2008 Foundation is an operating system which will let you enable basic IT resources like remote access, security and print sharing. It will offer you network foundation from where you can easily manage different setting on your systems which have got Windows operating system as well as on systems upon which you can run most of the famous business applications.
It also gives you familiar Windows user experience which will help you manage your business applications. You can also download Windows Server 2016 64 Bit ISO. Microsoft has announced that Windows Server 2008 Foundation can easily be upgraded to higher versions of Windows Server. This version of Windows is very suitable for small businesses which consist of not more than 15 people. Windows Server 2008 Foundation uses Windows Server Catalog for design. This version has enhanced the user experience and has come up with numerous features to give you fresh new feel. You can also download Windows Server 2012 R2.
Features of Dell OEM Windows Server 2008 Foundation x64 ISO Below are some noticeable features which you’ll experience after Dell OEM Windows Server 2008 Foundation x64 ISO free download. • Lets you enable basic IT resources like remote access and print sharing. • Offers you network foundation. • Gives you familiar Windows user experience. • Can manage you business applications. • Can easily upgrade to higher versions of Windows Server. • Suitable for small businesses.
• Uses Windows Server Catalog for design. • Enhanced user experience.